TUBO/TETRA usage patterns

low temp on demand – a few hits at the time, looove the flavor


extraction speed: slow
cloud size: low
number of hits: many

behavior: heat naturally increases in the beginning to reach displayed equilibrium temperature. the heater cools down after an on demand hit, expect to never fully hit the displayed temperature with the material.
execution: choose your low temperature, press the fire button and start



low temp cruise – flavor session


extraction speed: slow
cloud size: low
number of hits: many

behavior: cruise control presses the button for the user, hands-free operation possible. heat naturally increases a bit in the beginning to reach equillibrium temperature.
execution: choose your low temperature, double click the fire button, it will say “Cruise” on display and start



low temp warmup | w2c=0 – consistent low temp on demand


extraction speed: medium
cloud size: medium
number of hits: medium

behavior: warms the heater up, useful for when the device is cold to get things nicely prewarmed for further action.
execution: triple click the fire button, it will say “WarmUp” on display, wait for it to end and proceed with on demand (w2c=0) or cruise (w2c=1) operation.





warmup to cruise | w2c=1 – consistent performance


extraction speed: slow to fast (depending on temperature)
cloud size: medium to big (depending on temperature)
number of hits: few to many (depending on temperature)

behavior: warms the heater up first for consistent results from the start
execution: choose your temperature, triple click the fire button, it will say “WarmUp” on display, wait for it to end and start



high temp on demand


extraction speed: medium
cloud size: increasing
number of hits: medium

behavior: heat naturally increases in the beginning to reach displayed equillibrium temperature.
execution: choose your high temperature (eg. 200degC), press the fire button and start inhaling




high temp cruise


extraction speed: medium
cloud size: increasing
number of hits: medium

behavior: cruise control presses the button for the user, hands-free operation possible. heat naturally increases a bit in the beginning to reach equillibrium temperature.
execution: choose your high temperature (eg. 220degC), double click the fire button, it will say “Cruise” on display and start



high temp warmup – consistent clouds and quick bowls


extraction speed: fast
cloud size: big
number of hits: few

behavior: warms the heater up before starting for consistent results
execution: choose your high temperature (eg. 220degC), triple click the fire button, it will say “Warmup” on display, load the stem and wait for it to transition to "Cruise", start



warmuphit – no friggin time for nothing but this one hit!!


extraction speed: very fast
cloud size: big
number of hits: 1

behavior: fast cold start. heater warms up to 245degC and supplies a lot of heat for a start.
execution: triple click the fire button when the device is cold, it will say “WarmUp” on display, take one lung full fast inhale of around 15 seconds. Caution: do not take consecutive hits in warmup mode, there is a high risk of igniting the material.



Tempstepper upwards – temp stepping


extraction speed: slow to fast
cloud size: increasing
number of hits: few to many

behavior: increases temperature automatically after an amount of steps between a low and high temperature
execution: set timer, lowtemp, hightemp and steps in menu>vaping. click the fire button four times, it will say “Tstep 1 of X” on display, start inhalation. switch between steps with the + and - buttons





warmup to tempstepper | settings: w2c=2 – consistent performance from the get go lazy temp stepping


extraction speed: slow to fast (depending on temperature)
cloud size: medium to big (depending on temperature)
number of hits: few to many (depending on temperature)

behavior: warms the heater up before starting for consistent results
execution: choose your temperature, triple click the fire button, it will say “WarmUp” on display, wait for it to end and start



overtemp on demand - on demand – true on demand vapor


extraction speed: medium to fast
cloud size: medium to big
number of hits: few to many

behavior: heater is fired at high temperature to get everything warmed up quickly.
execution: choose your temperature around 20degC higher than your target temperature, start. gradually decrease temperature to your target temperature.



cruise with ecolvl 1-3 – save some energy in cruise


extraction speed, cloud size, number of hits a bit slower/less than normal cruise scenarios

behavior: lowers the heater temperature a bit to save energy when no air movement detected
execution: set menu>vaping>ecolvl to 1, double click the fire button, it will say “Cruise” on display until temperature is reached then change to “Eco”. inhale at any moment to activate the draw sensing. eco 0 = off, eco 1 = some savings, eco 2 = more savings eco 3 = max energy saving